1,372 research outputs found

    Patient-specific stopping power calibration for proton therapy planning based on single-detector proton radiography.

    Get PDF
    A simple robust optimizer has been developed that can produce patient-specific calibration curves to convert x-ray computed tomography (CT) numbers to relative stopping powers (HU-RSPs) for proton therapy treatment planning. The difference between a digitally reconstructed radiograph water-equivalent path length (DRRWEPL) map through the x-ray CT dataset and a proton radiograph (set as the ground truth) is minimized by optimizing the HU-RSP calibration curve. The function of the optimizer is validated with synthetic datasets that contain no noise and its robustness is shown against CT noise. Application of the procedure is then demonstrated on a plastic and a real tissue phantom, with proton radiographs produced using a single detector. The mean errors using generic/optimized calibration curves between the DRRWEPL map and the proton radiograph were 1.8/0.4% for a plastic phantom and -2.1/ - 0.2% for a real tissue phantom. It was then demonstrated that these optimized calibration curves offer a better prediction of the water equivalent path length at a therapeutic depth. We believe that these promising results are suggestive that a single proton radiograph could be used to generate a patient-specific calibration curve as part of the current proton treatment planning workflow

    paRTner: UK-Africa partnership for radiotherapy

    Get PDF
    Kate Ricketts and Gary Royle reflect on the first year of the paRTner project, a global health partnership for radiotherapy between the UK and Ghana

    Range verification for eye proton therapy based on proton-induced x-ray emissions from implanted metal markers.

    Get PDF
    Metal fiducial markers are often implanted on the back of the eye before proton therapy to improve target localization and reduce patient setup errors. We aim to detect characteristic x-ray emissions from metal targets during proton therapy to verify the treatment range accuracy. Initially gold was chosen for its biocompatibility properties. Proton-induced x-ray emissions (PIXE) from a 15 mm diameter gold marker were detected at different penetration depths of a 59 MeV proton beam at the CATANA proton facility at INFN-LNS (Italy). The Monte Carlo code Geant4 was used to reproduce the experiment and to investigate the effect of different size markers, materials, and the response to both mono-energetic and fully modulated beams. The intensity of the emitted x-rays decreases with decreasing proton energy and thus decreases with depth. If we assume the range to be the depth at which the dose is reduced to 10% of its maximum value and we define the residual range as the distance between the marker and the range of the beam, then the minimum residual range which can be detected with 95% confidence level is the depth at which the PIXE peak is equal to 1.96 σbkg, which is the standard variation of the background noise. With our system and experimental setup this value is 3 mm, when 20 GyE are delivered to a gold marker of 15 mm diameter. Results from silver are more promising. Even when a 5 mm diameter silver marker is placed at a depth equal to the range, the PIXE peak is 2.1 σbkg. Although these quantitative results are dependent on the experimental setup used in this research study, they demonstrate that the real-time analysis of the PIXE emitted by fiducial metal markers can be used to derive beam range. Further analysis are needed to demonstrate the feasibility of the technique in a clinical setup

    Solid Phase Micro Extraction: Potential for Organic Contamination Control for Planetary Protection of Life-Detection Missions to the Icy Moons of the Outer Solar System

    Get PDF
    Conclusively detecting, or ruling out the possibility of, life on the icy moons of the outer solar system will require spacecraft missions to undergo rigorous planetary protection and contamination control procedures to achieve extremely low levels of organic terrestrial contamination. Contamination control is necessary to avoid forward contamination of the body of interest and to avoid the detection of false positive signals which could either mask indigenous organic chemistry of interest or cause an astrobiological false alarm. Here we test a new method for rapidly and inexpensively assessing the organic cleanliness of spaceflight hardware surfaces using solid phase micro extraction (SPME) fibres to directly swab surfaces. The results suggest that the method is both time and cost efficient. The SPME-gas chromatography mass spectrometry (GC-MS) method is sensitive to common mid-weight, non-polar contaminant compounds, e.g. aliphatic and aromatic hydrocarbons, which are common contaminants in laboratory settings. While we demonstrate the potential of SPME for surface sampling, the GC-MS instrumentation restricts the SPME-GC-MS technique’s sensitivity to larger polar and non-volatile compounds. Although not used in this study, to increase the potential range of detectable compounds, SPME can also be used in conjunction with high performance liquid chromatography/liquid chromatography-mass spectrometry systems suitable for polar analytes [Kataoka et al., 2000]. Thus, our SPME method presents an opportunity to monitor organic contamination in a relatively rapid and routine way that produces information-rich data sets

    A Geant4 Fano test for novel very high energy electron beams

    Get PDF
    Objective. The boundary crossing algorithm available in Geant4 10.07-p01 general purpose Monte Carlo code has been investigated for a 12 and 200 MeV electron source by the application of a Fano cavity test. Approach. Fano conditions were enforced through all simulations whilst varying individual charged particle transport parameters which control particle step size, ionisation and single scattering. Main Results. At 12 MeV, Geant4 was found to return excellent dose consistency within 0.1% even with the default parameter configurations. The 200 MeV case, however, showed significant consistency issues when default physics parameters were employed with deviations from unity of more than 6%. The effect of the inclusion of nuclear interactions was also investigated for the 200 MeV beam and was found to return good consistency for a number of parameter configurations. Significance. The Fano test is a necessary investigation to ensure the consistency of charged particle transport available in Geant4 before detailed detector simulations can be conducted

    A methodology to extract outcomes from routine healthcare data for patients with locally advanced non-small cell lung cancer

    Get PDF
    BACKGROUND: Outcomes for patients in UK with locally advanced non-small cell lung cancer (LA NSCLC) are amongst the worst in Europe. Assessing outcomes is important for analysing the effectiveness of current practice. However, data quality is inconsistent and regular large scale analysis is challenging. This project investigates the use of routine healthcare datasets to determine progression free survival (PFS) and overall survival (OS) of patients treated with primary radical radiotherapy for LA NSCLC. METHODS: All LA NSCLC patients treated with primary radical radiotherapy in a 2 year period were identified and paired manual and routine data generated for an initial pilot study. Manual data was extracted information from hospital records and considered the gold standard. Key time points were date of diagnosis, recurrence, death or last clinical encounter. Routine data was collected from various data sources including, Hospital Episode Statistics, Personal Demographic Service, chemotherapy data, and radiotherapy datasets. Relevant event dates were defined by proxy time points and refined using backdating and time interval optimization. Dataset correlations were then tested on key clinical outcome indicators to establish if routine data could be used as a reliable proxy measure for manual data. RESULTS: Forty-three patients were identified for the pilot study. The manual data showed a median age of 67 years (range 46- 89 years) and all patients had stage IIIA/B disease. Using the manual data, the median PFS was 10.78 months (range 1.58-37.49 months) and median OS was 16.36 months (range 2.69-37.49 months). Based on routine data, using proxy measures, the estimated median PFS was 10.68 months (range 1.61-31.93 months) and estimated median OS was 15.38 months (range 2.14-33.71 months). Overall, the routine data underestimated the PFS and OS of the manual data but there was good correlation with a Pearson correlation coefficient of 0.94 for PFS and 0.97 for OS. CONCLUSIONS: This is a novel approach to use routine datasets to determine outcome indicators in patients with LA NSCLC that will be a surrogate to analysing manual data. The ability to enable efficient and large scale analysis of current lung cancer strategies has a huge potential impact on the healthcare system
    • …